ACH550 - ABB HVAC Standard Drive
 | ABB ACH550 standard AC inverter HVAC drives are simple to buy, install, configure and use, saving considerable time. They are widely available through ABB Drives Alliance, hence the use of the term standard. The drives have common user and process interfaces with fieldbuses, common software tools for sizing, commissioning, maintenance and common spare parts.
| | The introduction of a dedicated ABB AC inverter for HVAC marks a significant milestone in the development of AC frequency inverters. Macros for the most common applications are built into the drive as standard. The drive is programmed with several HVAC applications, including supply and return fans, cooling tower fans, booster pumps and condensers. |
| Highlights | Options | - Intuitive use with a wide range of interactive assistants & control panel
- Real time clock & calendars and inbuilt timers
- Swinging choke for superior harmonic reduction
- Ambient Temperature up to 50oC
- Vector control
- Coated boards for harsh environments
- Inbuilt category C2 EMC filter (1st environment) as standard
- Flexible fieldbus system with inbuilt Modbus and numerous internally mountable fieldbus adapters including BACnet
- UL, cUL, CE, C-Tick and GOST R approved
- RoHS compliant
| - Fieldbuses
- DeviceNet
- LONWORKS®
- PROFIBUS DP
- Panel mounting kit
- DriveWindow Light 2 software
|
| ACH550 - Ratings, Types and Voltages | | Wall Mounted Units | | 3 - phase supply voltage 380-480 V | | Ratings | Frame | Fuse Size Type gG | Heat Dissipation
| Cooling Needs
| Type | | Normal use | | kW | A | (w) | m3/h | | 0.75 | 2.4 | R1 | 10 | 30 | 44 | ACH550-01-02A4-4 | | 1.1 | 3.3 | R1 | 10 | 40 | 44 | ACH550-01-03A3-4 | | 1.5 | 4.1 | R1 | 10 | 52 | 44 | ACH550-01-04A1-4 | | 2.2 | 5.4 | R1 | 10 | 73 | 44 | ACH550-01-05A4-4 | | 3 | 6.9 | R1 | 10 | 97 | 44 | ACH550-01-06A9-4 | | 4 | 8.8 | R1 | 10 | 127 | 44 | ACH550-01-08A8-4 | | 5.5 | 11.9 | R1 | 16 | 172 | 44 | ACH550-01-012A-4 | | 7.5 | 15.4 | R2 | 16 | 232 | 88 | ACH550-01-015A-4 | | 11 | 23 | R2 | 25 | 337 | 88 | ACH550-01-023A-4 | | 15 | 31 | R3 | 35 | 457 | 134 | ACH550-01-031A-4 | | 18.5 | 38 | R3 | 50 | 562 | 134 | ACH550-01-038A-4 | | 22 | 45 | R3 | 50 | 667 | 134 | ACH550-01-045A-4 | | 30 | 59 | R4 | 63 | 907 | 280 | ACH550-01-059A-4 | | 37 | 72 | R4 | 80 | 1120 | 280 | ACH550-01-072A-4 | | 45 | 87 | R4 | 125 | 1440 | 280 | ACH550-01-087A-4 | | 55 | 125 | R5 | 160 | 1940 | 350 | ACH550-01-125A-4 | | 75 | 157 | R6 | 200 | 2310 | 405 | ACH550-01-157A-4 | | 90 | 180 | R6 | 250 | 2810 | 405 | ACH550-01-180A-4 | | 110 | 195 | R6 | 250 | 3050 | 405 | ACH550-01-195A-4 | | 132 | 245 | R6 | 315 | 3260 | 405 | ACH550-01-246A-4 | | | | Free Standing Units | | 160 | 289 | R7 | - | - | - | ACH550-01-289A-4 | | 200 | 368 | R8 | - | - | - | ACH550-01-368A-4 | | 250 | 486 | R8 | - | - | - | ACH550-01-486A-4 | | 280 | 526 | R8 | - | - | - | ACH550-01-526A-4 | | 315 | 602 | R8 | - | - | - | ACH550-01-602A-4 | | 355 | 645 | R8 | - | - | - | ACH550-01-645A-4 | | Includes EMC Filter. Protection IP21 available ex-stock and IP54 on request. |
| Drive Dimensions | | Wall Mounted Units | | Frame Size
| Dimensions (mm) & Weights | | IP21 / UL type 1 | IP54 / UL type 12 | | H1 | H2 | W | D | kg | H | W | D | kg | | R1 | 369 | 330 | 125 | 212 | 6.5 | 449 | 213 | 234 | 8.2 | | R2 | 469 | 430 | 125 | 222 | 9 | 549 | 213 | 245 | 11.2 | | R3 | 583 | 490 | 203 | 231 | 16 | 611 | 257 | 253 | 18.5 | | R4 | 689 | 596 | 203 | 262 | 24 | 742 | 257 | 284 | 26.5 | | R5 | 739 | 602 | 265 | 286 | 34 | 776 | 369 | 309 | 38.5 | | R6 | 880 | 700 | 300 | 400 | 69 | 924 | 410 | 423 | 80 | | | | Free Standing Units | | R5 | 1507 | N/A | 250 | 520 | 115 | - | - | - | - | | R6 | 2024 | N/A | 347 | 617 | 230 | - | - | - | - |
| H1 = Height with cable connection box. H2 = height without cable connection box. W = Width D = Depth
|
|
|